122
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices ~ Appendix E: Serial Commands
PRGSTRING - Program String
This command sets/reports a programmed string.
Command form: DEVICE
PRGSTRING
<ID> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
PRGSTRING Command
ID 0 – 7 (string location)
Value 1–80 Characters
CLEAR = Clear current value
Null = Current value
Example:
#53 PRGSTRING 2 MUTE
On XAP 800 unit 3 (
#53
), string
location
2
is programmed (
PRGSTRING
) with
MUTE
.
Supported special characters
\a = alert
\b = backspace
\f = formfeed
\n = new line
\r = carriage return
\t = horizontal tab
\v = vertical tab
\\ = backslash