DFLTM - Default Meter
This command selects/reports the setting of the default meter.
Command form: DEVICE
DFLTM
[Channel] [Group] [Position]
Argument details
Name Description
Device 0–7 or * to select all units
DFLTM Command form
Channel 1–12
Group I = Inputs, O = Outputs, M = Mic Inputs, L= Line Inputs
Position I, A, N, G, as applicable for group
(see Meter Type definitions, page 94)
Example:
#45 DFLTM 8 O A
On PSR1212 unit 5 (
#45
), the default meter
(
DFLTM
) is set to output (
O
)
8
after the gain adjustment (
A
).
DID - Device ID
This command selects/reports the device ID.
Command form: DEVICE
DID
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
DID Command form
Value 0–7 (select device ID)
Example:
#47 DID 0
On PSR1212 unit 7 (
#47
), the device ID (
DID
) is set to
0
.
Appendices ~ Appendix E: Serial Commands